Moving the Same Safety Function From a 440R Relay to GuardLogix: What the Rung Replaces and What It Does Not

plc programming 440r relay to guardlogix dcs what the rung replaces 1 plc

The guard on the case packer came off its 440R-S12R2 on a Saturday and went onto a 1791ES-IB8XOBV4 under a GuardLogix 5580, same tongue switch, same two 100S-C09 contactors, and the first time the door was closed the DCS instruction reported Fault Code 16#4000 and would not take a reset. Channel A active, channel B … Read more

A Safety Signal Between Two GuardLogix Controllers: CIP Safety Produced and Consumed

plc programming cip safety produced consumed tags two guardlogix 1 plc

The infeed conveyor’s GuardLogix 5580 consumes one safety tag from the case packer’s 5580, CP_Safe, and at 02:04 every night for a week CP_Safe.ConnStatus.ConnectionFaulted went to 1 for between two and nine seconds, the consumed data went to zero, the conveyor’s CROUT dropped its contactors, and the shift lead reset it and wrote “network” on … Read more

One Photo-Eye, Two Signals: Light-Operate, Dark-Operate and the Setting That Inverted Your Zone Logic

One retroreflective 42EF with its reflector, beam made on an empty zone and beam broken by a carton, and below it the output and LED state of a light-operate J model and a dark-operate K model in each case

Zone 6’s eye came out of stores as a 42EF-P2KBB-F4, went onto the bracket in place of a 42EF-P2JBB-F4, and from the next 600 mm carton on, zone 6 reported occupied while it was empty and empty while a carton stood on it. One letter in the fifth position of the catalogue number, K for … Read more

Moving an S7-315 Program onto an S7-1500: What the Migration Converts and What It Hands Back to You

The two-stage path from a STEP 7 V5.x project to an S7-1500 program, with the CPU 315-2 PN/DP rack and its addresses on one side and the CPU 1515-2 PN with no modules on the other

A CPU 315-2 PN/DP with 6ES7315-2EH14-0AB0 on the label maps to a CPU 1515-2 PN, 6ES7515-2AM01-0AB0, in the Siemens migration guide’s CPU table, and the S7-1500 migration does not happen in one move. It happens in two, the second of which is a right-click on the old CPU in the device view called Migrate to … Read more

Building a Two-Step Sequence in TIA Portal GRAPH: Transitions, Interlocks and the Step That Never Advances

The two-step sequencer in the sequence view: S1 Fill, T1, S2 Heat expanded to show its action table, interlock network, supervision network and transition T2, and the jump from T2 back to S1; below it the call from OB1 with the standard interface parameters

Step 2 of a two-step TIA Portal GRAPH sequencer on a CPU 1515-2 PN has been active for 4 minutes 12 seconds by its own S2.T, the transition below it has been satisfied for the last 40 of those seconds, and the sequencer is still sitting on step 2. The heater that step 2 drives … Read more

Catching an Intermittent Bit on an S7-1500 with a Trace: Trigger Condition, Sample Rate and Recording Length

plc programming s7 1500 trace intermittent bit trigger sample rate recording length 1 plc

Zone 3 of the takeaway conveyor stops about once a shift with “Zone3”.Fault latched, the photo-eye on %I4.3 reads a steady 1 in every watch table anybody has opened, and the CPU 1516-3 PN/DP is turning OB1 over in about 6 ms. Whatever is happening is happening inside one of those 6 ms passes, hours … Read more

Advertisement