Cross-Fault Detection Between Two Safety Channels: What a Short Between the Wires Looks Like to the Controller

plc programming cross fault detection two safety channels 1 plc

Inputs I0 and I1 on a 1791ES-IB8XOBV4 went solid red one afternoon with the guard closed, and the DCS instruction in the GuardLogix 5580 behind them has held Input Status false ever since. The guard switch on the infeed has two NC contacts in one four-core cable, the cable was crushed where it enters the … Read more

Photo-Eye Placement on an Accumulation Zone: Distance From the Discharge and What a Long Box Does

Three zones in side view with the eye 150 mm back from the discharge: a stopped 600 mm carton with 750 mm of zone behind it, and a stopped 1219 mm carton with 131 mm

A 42EF retroreflective eye bolted 150 mm back from the discharge roller of a 1.5 m zone stops a 600 mm carton with 750 mm of zone still behind it, and stops a 1219 mm carton with 131 mm. Move the same eye to 50 mm from the discharge and the first carton overshoots into … Read more

Singulation on a Zero-Pressure Accumulation Conveyor: The Release Rule That Stops Two Boxes Leaving Together

Four accumulation zones with eye positions, the 1.5 m pitch, and the length of conveyor that no photo-eye covers

On a 1.5 m zone pitch at 0.28 m/s, a 600 mm carton is invisible to both photo-eyes for 3.2 seconds of its journey between them. An upstream zone whose release permissive is nothing more than “the next eye is clear” will use that window to send a second carton, and the two of them … Read more

A Conveyor Jam Timer That Does Not Nuisance-Trip: Setting the Time From Zone Length and Belt Speed

Three zones of an accumulation conveyor with zone length, photo-eye position and belt speed marked, and the eye-to-eye pitch that sets the transit timer

Time it with a stopwatch before you type anything into the preset: the longest carton you run, crossing the photo-eye, on the slowest zone. A 1219 mm carton at 0.28 m/s sits on that eye for 4.35 seconds, which is why the 2000 ms that came across with the copied project trips every time the … Read more

One Photo-Eye, Two Signals: Light-Operate, Dark-Operate and the Setting That Inverted Your Zone Logic

One retroreflective 42EF with its reflector, beam made on an empty zone and beam broken by a carton, and below it the output and LED state of a light-operate J model and a dark-operate K model in each case

Zone 6’s eye came out of stores as a 42EF-P2KBB-F4, went onto the bracket in place of a 42EF-P2JBB-F4, and from the next 600 mm carton on, zone 6 reported occupied while it was empty and empty while a carton stood on it. One letter in the fifth position of the catalogue number, K for … Read more