A Safety Reset That Is a Rising Edge, Not a Level: The One Rung That Stops an Automatic Restart

The reset station three ways: the blue momentary button wired from T2 to I4 as designed, the same button taped down, and a jumper or a held HMI bit across the contact

The guard on the case packer closed at 14:07 and the infeed conveyor started on its own, with the blue reset button 4 m away and nobody within reach of it. The DCS instruction on that gate was configured Restart Type Manual, exactly as the drawing said, and the machine still restarted, because the button … Read more

Commanding a PowerFlex 525 from a ControlLogix: The Command Word, the Reference and the Status Bits

Bit 0 of the PowerFlex 525 logic command word is Normal Stop, and it has to be sitting at 0 before bit 1 will ever start the drive. That footnote under the table in Appendix D of 520COM-UM001 is behind most of the drives that show a green connection in the I/O tree and still … Read more