Time Sync Across a Cell: PTP on EtherNet/IP, NTP on PROFINET, and Why the Two Logs Disagree

A cell with a 1756-TIME GPS grandmaster feeding a Stratix 5400 in boundary mode on the EtherNet/IP side and an S7-1500 NTP client on the PROFINET side, showing what each half receives and what is deactivated by default

The guard door opens once and gets recorded twice: 06:41:12.310 in the Logix log, 06:41:12.650 in the S7-1500’s diagnostics buffer. The two controllers are eight metres apart on the same machine, both nominally synchronised, and the gap is a third of a second every time you look. Neither clock is broken. The Logix side is … Read more

Unicast or Multicast on an EtherNet/IP I/O Connection: the Checkbox and What It Decides

Two drawings of the same drop: on the left, unicast, where a 1756-EN2T owner at 192.168.1.10 receives one stream from a 1734-AENTR at 192.168.1.50 and a second controller at 192.168.1.11 receives nothing, its listen-only connection rejected with 16#0106; on the right, multicast, where the adapter sends one stream to a group address and the switch delivers it to both controllers, with the owner and the listen-only connection both marked multicast

Unicast or Multicast on an EtherNet/IP I/O Connection: the Checkbox and What It Decides Module fault 16#0106 appeared on the second controller’s listen-only copy of a 1734-AENTR drop, and the string underneath it reads “Module owned and configured by another controller. Module may accept only one connection if Unicast is used.” The owning controller had … Read more

Catching a PLC Intermittent Fault with a Trend in the Controller: the Tags, the Rate, and the Latch That Keeps the Data

Eight tags in the PLC intermittent fault trend with where each comes from, how often it can change, and why it is in

Line 2’s palletiser infeed stops about once a shift with Infeed_Jam latched, the alarm log says “Infeed jam” with a time, and the 1756-L83E, the PowerFlex 525 and the 1756-IB16 feeding the discharge photo-eye all check out every time somebody looks. Whatever happens takes a few tens of milliseconds and happens hours apart, and the … Read more

Cross-Fault Detection Between Two Safety Channels: What a Short Between the Wires Looks Like to the Controller

plc programming cross fault detection two safety channels 1 plc

Inputs I0 and I1 on a 1791ES-IB8XOBV4 went solid red one afternoon with the guard closed, and the DCS instruction in the GuardLogix 5580 behind them has held Input Status false ever since. The guard switch on the infeed has two NC contacts in one four-core cable, the cable was crushed where it enters the … Read more