Kinetix 5700 DC Bus Sharing: What the Bus Supply Carries and Where the Limit Is

Two boxes joined by an orange cable: a power supply cluster holding a 2198-P208, a 2198-S086, a 2198-D020, a 2198-D006, a 2198-CAPMOD-2240 and a 2198-CAPMOD-DCBUS-IO extension module, and an extended cluster holding the same accessory pair followed by three inverters, with the customer-supplied DC-bus cable rated 104 A between them and the note that both boxes are one DC-bus group

Kinetix 5700 DC Bus Sharing: What the Bus Supply Carries and Where the Limit Is A 2198-P208 supports 13,000 µF of total system capacitance and puts out 46 kW continuously. Those are two separate ceilings, they get reached by two different kinds of machine, and on most rails the one that stops you first is … Read more

The Kinetix 5700 Power Rail: What Each Module Is, and the Order They Go In

A Kinetix 5700 rail drawn left to right with seven modules: a 2198-P208 DC-bus power supply at 85 mm, a 2198-S160-ERS4 single-axis inverter at 100 mm, a 2198-S086-ERS4 at 85 mm, two dual-axis inverters and two accessory modules at 55 mm each, with the DC-bus link lengths marked above each joint and end caps at both ends

The Kinetix 5700 Power Rail: What Each Module Is, and the Order They Go In A 2198-D032-ERS4 is 55 mm wide, a 2198-S160-ERS4 is 100 mm, and the DC-bus link that joins one module to the next is a moulded part in a fixed length that arrives in the box with the module. There is … Read more