Reply
RE: Case packer count on a 1769-L33ER always runs over the tally, worse on jam days

Trend the count against the run bit for a week. You'll see every jog on it.

2 weeks ago
Reply
RE: Downtime reasons and OEE on a CompactLogix, or let the historian work it out

Fair enough on the buffer, our short stops were always a guess.

2 weeks ago
Reply
RE: Case packer count on a 1769-L33ER always runs over the tally, worse on jam days

That swing is never a sensor. What happens on a bad day that doesn't happen on a good one?

2 weeks ago
Reply
RE: Downtime reasons and OEE on a CompactLogix, or let the historian work it out

We did ours off the run bit in the SCADA for two years and it was fine. You put a 5 second filter on the transition so short jams roll up, and a dropd...

2 weeks ago
Reply
RE: Laying tags out on a 1756-L83E now so a per station shift report is possible later

Built it over the weekend. One UDT called Stn_Data with Count, Rejects, RunMinutes, a 20 character name string and a DINT for the last stamp, then Sta...

2 weeks ago
Reply
RE: Laying tags out on a 1756-L83E now so a per station shift report is possible later

FactoryTalk Historian SE, and the point list in it was typed in by hand by whoever set it up. That's half the reason it's a mess, nobody has touched t...

2 weeks ago
Reply
RE: CompactLogix 1769 bank, slot 4 faults 16#0114 after a download, rest of the rack fine

Card in slot 4 is a 1769-IQ16F. The crib spare is an IQ16F as well, so both of the cards I tried were the fast version and the project has plain IQ16 ...

3 weeks ago
Reply
RE: CompactLogix 1769 bank, slot 4 faults 16#0114 after a download, rest of the rack fine

Six modules and no change to the count for two years, so I don't think we're over anything. Pulled the ECR off and refitted it anyway, no difference. ...

3 weeks ago
Reply
RE: CompactLogix 1769 bank, slot 4 faults 16#0114 after a download, rest of the rack fine

v33 here. Tree says 1769-IQ16, Series A, and the Connection tab says Module Fault, 16#0114, something about an electronic keying mismatch and a produc...

3 weeks ago
Reply
RE: TLS3-GD2 guard lock releases a second after Stop while the spindle is still coasting

Coast time with the heaviest wheel goes in the validation file, not the bench number.

3 weeks ago
Reply
RE: Kinetix 5700 axis fault excessive position error at the end of fast moves

Keep that trend screenshot with the project. Next person will want it.

3 weeks ago
Reply
RE: TwinCAT EtherCAT at 250 us with 30 slaves, cycle time exceeded and motion jitter

The other three haven't had antivirus put on them yet. Give it time.

3 weeks ago
Reply
RE: PanelView Plus 7 jog button kept the Kinetix axis moving after the Ethernet was unplugged

Sounds like the watchdog tripping on a late Second update. I reckon 3 s is tight for a terminal that's also drawing screens. Compare against the last ...

3 weeks ago