Meter the loop again with the well quiet and then again when it's spiking, but do it at the sensor head, not at the card. If it swings at the head too...
Forty rigs with a red stop button. Somebody should tell them.
Clip was heating the fuse for months. Then one hot day.
Three weeks ago is when the fog started. Drive goes back on the shelf.
A bolted guard is why nobody checks rotation. Ours is the same, two people and a torch.
Ferrites would have looked busy and fixed nothing.
Top four running, bottom four idle with a full bus. That's the whole difference.
Owner went for the small SCADA. Ignition on one PC, smallest licence the integrator could put together, one client, all eight machines, running and st...
Checked, it was HRUI already. So I read the manual again, page 43, and the energy registers are marked "MSW first", the opposite of the power ones. Sa...
Pulled a week out of the historian for the four drives. About 6 kW each, flat, all shift. No saving to chase then. Constant torque at full speed, sam...
Read the scale factor register, it holds -1. Applied it in the ladder as ten to that power times the raw value. 187.4 kW, 231.0 A, matches the display...
Stores buys what's cheap. Put a note on the bin.
There's a step by step here:/p>
The twist cancels what both wires see equally. Motor leads a finger away from one side of the pair don't hit both wires equally. The shield takes it a...
Went back to the integrator with "smallest edition that logs, one PC, one client". Price came down to a bit under double the PanelView. Owner's thinki...